Conventional feedback
|
Feedback with efector valvis |
|
Valve position |
Feedback of up to 2 positions
(open, closed). |
Feedback of 3 positions
(open, closed, seat lift). |
|
Installation time |
Mounting of 2 proximity sensors with mechanical brackets that must be continuously adjusted for the setpoints. |
Only one unit to install -
time saving approximately 75% |
|
Adjustment |
Alignment of the position sensors
to the valve position. Possibly readjustment in case of seal wear.
|
Position adjustment via pushbutton -
time savings approximately 90% |
|
Predictive maintenance |
No option to monitor the seal wear. |
Alarm feedback if the seal
parameters change. |
|
|
|
|